Questions about commercial doors, hardware, access control and code — asked by the people who have to live with the answer. Ask one and it may end up here.

What's the right lockdown hardware for classrooms?

Locks that can be locked from inside the room without opening the door, still open in one motion from inside, and can be opened from outside with a key.

Classroom security locksets are built for exactly that.

Can you review a Division 08 hardware schedule before bid?

Yes, and that's the cheapest time to do it. Each set is checked against the door schedule, the plans, and code: function, grade, handing, and listings for rated openings.

Why does the bar take a shove to open?

Usually the latch is under load. A door that's dropped or a frame that's shifted puts pressure on the latch bolt, so it can't retract cleanly. Weatherstripping that's too tight or building air pressure pushing against the door does the same thing.

The fix is usually alignment and adjustment, not a new device.

Fail-safe or fail-secure — which do we need?

It depends on the door. Fail-safe unlocks when power is lost; fail-secure stays locked from the outside.

Fire doors need to stay latched, so their electrified hardware is fail-secure. Free egress from inside is required either way.

Is an annual fire door inspection actually required?

Yes. NFPA 80 requires fire door assemblies to be inspected and tested at least once a year, with a written record kept for the authority having jurisdiction.

Why Grade 1 hardware for public buildings?

Public buildings take heavy, unpredictable traffic and have to last between capital budgets. Grade 1 hardware is tested for exactly that duty.

Why are fire doors such a common survey finding in healthcare?

Healthcare buildings have more rated openings than most, heavy cart and bed traffic that knocks hardware out of adjustment, and surveyors who check them closely.

How often should commercial doors be serviced?

It depends on traffic. Busy entrances and storefronts benefit from quarterly visits; quieter interior doors may only need an annual check.

Fire-rated doors need an annual NFPA 80 inspection regardless.

Why do the batteries keep dying?

Usually because the lock is working too hard. A bolt that drags against the strike makes the motor pull more current every cycle.

Fixing the alignment often fixes the battery life.

Why does the door stop latching after new weatherstripping?

The seal is too aggressive for the closer. A seal that compresses hard pushes the door back off the strike.

The fix is the right seal for the gap, not a stronger closer.

Do we need new locks after an employee leaves?

Usually not. Most commercial locks can be rekeyed, which changes which keys work without replacing the hardware.

With interchangeable cores, it's a quick core swap at each door.

Can one vendor really cover every door?

For mechanical and electrified door hardware, yes — closers, exit devices, locks, hinges, seals, inspections, and the records behind them.

One vendor means one standard and one set of records.

What door-related records should an owner have?

An annual fire door inspection record for every rated opening, ADA measurements for public-facing doors, and a key record.

How fast can a pre-sale assessment be done?

It depends on the number of openings; it's quickest when access is already being arranged for other inspections.

Tell me the timeline up front.

How does a preferred vendor arrangement work?

Scheduled visits across the portfolio, set by building type and traffic, plus priority response and one documentation format for every property.

Is there a minimum job size?

No. A single door is a job.

What format are the records in?

One PDF per building, organized by opening number, with what was inspected, measured, and corrected.

Can you review a quote remotely?

Yes. Tell me about the job through the form, and once we've talked I'll ask for the quote, the door schedule if there is one, and a few photos of the openings.

Most second opinions don't need a site visit.

We've replaced the same part twice. Why does it keep failing?

Because the part probably isn't the problem. A closer that keeps failing is often on a door that's moved; a strike that keeps failing is often on a door with a power or alignment problem.

The fix is finding the cause, not replacing the symptom again.

Why does our storefront door slam?

Most storefront closers are out of adjustment, not broken. Cold weather and heavy traffic make it worse. It's usually a quick fix.

Do apartment unit entry doors have to be fire-rated?

In most apartment buildings, unit entry doors that open onto a rated corridor are fire-rated and required to be self-closing.

A unit door that doesn't close and latch on its own is a common finding.

Is the door warped, or is it the hinges?

Almost always the hinges. Worn knuckles and loose screws let the door drop on the latch side, which looks like a warped door.

Uneven gaps around the door are the giveaway.

How high can a threshold be on an accessible entrance?

ADA limits thresholds to 1/2 inch, with beveled edges. Some older entrances are allowed up to 3/4 inch if beveled.

Higher than that is a trip hazard and a compliance problem.

What's the ADA opening force limit for our entrance?

ADA sets a 5-pound limit for interior doors. Exterior entrances are often regulated by the local building code instead.

Either way, a heavy entrance door is a complaint waiting to happen.

Is ADA remediation expensive?

Usually less than owners expect. Most failures are closer adjustment, not replacement.

Can you take over buildings with no records?

Yes. The first cycle creates the baseline for each property.

Can you provide documentation for a capital plan?

Yes. A condition report per opening shows what's serviceable, what's near end of life, and what's out of compliance.

Why does the door only fail in winter?

Cold slows closer fluid, shrinks and shifts frames, and changes building air pressure. All three show up in January and disappear in April.

Can you get a door ready before the CO inspection?

Usually. Send the list and the inspection date.

Egress function, positive latching on rated doors, and ADA opening force are the items that hold up a CO most often.

How do you evaluate a substitution request?

Same function, same grade, same listings. If a substitute matches all three and fits the door and frame preps, it's usually acceptable.

If not, it isn't, regardless of price.

What fails most often?

Doors that close but don't latch, doors propped or held open with unapproved devices, painted-over labels, and gaps under the door that grew when the flooring changed.

What's the difference between Grade 1 and Grade 2 locks?

Grades come from ANSI/BHMA testing for cycles, strength, and security. Grade 1 is built for heavy commercial traffic; Grade 2 for light commercial.

Main entrances, stairwells, and busy corridors should be Grade 1.

Why do hinge screws keep working loose?

Usually because the holes are stripped. New screws in old holes don't hold.

The holes need to be repaired properly, or the hinge needs through-bolts or longer screws into solid material.

What is ligature-resistant hardware?

Hardware designed to remove anchor points in behavioral health areas. It has to be chosen for the specific risk level of each space.

Are magnetic locks allowed on exit doors?

In limited cases, with conditions: a sensor that releases the lock as someone approaches, a manual release button, and release on fire alarm and power loss.

They're often the wrong choice where a properly specified electrified lock or strike would do.

We don't have any fire door records. Where do we start?

With an inspection of the rated openings. That creates the record, and the findings become the first repair list.

Does a plan include the annual fire door inspection?

It can, and that's usually the most efficient way to do it: the inspection and the adjustments it calls for happen on the same visit.

What does a spec review cost compared with getting it wrong?

A review costs a fraction of what it costs to replace hardware that arrived with the wrong function, grade, or listing.

The cheapest time to fix an opening is on paper.

Why do stairwell doors keep getting propped open?

Usually because the closer is set too heavy or the latch doesn't line up. Fix those and the propping usually stops.

Standalone keypad or networked access?

Standalone works well for a few doors with a few codes.

Once you're changing codes on several doors at once, or need an audit trail of who came in when, networked or credential-based access pays for itself.

What is dogging, and when is it allowed?

Dogging holds the latch retracted so the door works as push/pull during business hours. It's fine on non-rated exit devices.

It isn't allowed on fire exit hardware, because a fire door has to latch every time it closes.

When should school door work be scheduled?

Summer for anything major. Inspections and adjustments can happen during the year, around the school day.

Who usually asks for these records?

The fire marshal or code official, insurers, and anyone buying, leasing, or financing the building.

Who is the report written for?

Buyers, sellers, and lenders — people making a financial decision, not hardware specialists. Each finding comes with an indicative scope.

Access control releases the lock, but the door stays shut. Whose problem is that?

Usually the door's. The lock released, but the latch or strike is under load from a door that's dropped or a frame that's shifted.

That's a hardware problem, not a panel problem.

What do we get after each visit?

A record per opening: what was checked, what was adjusted, and what needs attention before the next visit.

Do you work with architects or with owners?

Both. Owners usually want a second opinion on a quote. Architects and GCs usually need a hardware schedule written or checked — see Hardware Scheduling.

Can you assess a whole portfolio?

Yes, with one report format across every building so they can be compared.

Can you work through BOCES or cooperative purchasing?

Ask. The vendor registration page lists the paperwork available — W-9 and the rest of the vendor packet.

Can rekeys between tenants be handled consistently?

Yes. Every turnover is done the same way and recorded, so the building always knows which keys are in circulation.

Can we add a deadbolt to an exit door?

Usually not on a required exit. Egress doors have to open in one motion from the inside. A separate deadbolt adds a second motion.

Mortise locks with a deadbolt that retracts when the lever is turned are the standard way to get both.

Can you document doors someone else maintains?

Yes. The inspection and measurements stand on their own, whoever does the repairs.

Can failures be fixed during the inspection?

Many can. Most failures are adjustment or parts — closers, latches, hold-opens, coordinators — not replacement.

How is ADA compliance checked?

Measured, not eyeballed: opening force with a gauge, closer timing, hardware height, and whether the hardware works without tight grasping or twisting.

Can we put a keypad on a door with a panic bar?

Yes, with keypad exit trim. It controls entry only. The panic device still has to release in one motion from inside.

What hardware holds up in a commercial kitchen?

Finishes and exit devices chosen for grease, moisture, and cleaning chemicals — usually stainless or heavy-duty coated finishes rather than what's on the front door.

Do you work with municipal procurement?

Yes — vendor registration, W-9, and references.

The reader beeps green but the door doesn't open. Why?

Usually the lock released but the latch is bound against the strike, or the power transfer through the hinge has failed. Both are door-side problems.

Can you coordinate hardware for tenant improvements?

Yes. Getting the functions right during fit-out avoids reworking doors after move-in.

Do tenant turnover rekeys fit in?

Yes — handled the same way at every property and recorded in the key file.

Can we add weatherstripping to a fire door?

Only products listed for use on fire-rated assemblies. Adding an unlisted seal can void the door's rating.

When does a continuous hinge make sense?

On heavy, high-traffic doors that keep sagging even after hinge replacement — school entrances, storefronts, busy service doors.

It spreads the load along the full height of the door and ends the repeat calls.

Which type of exit device do we need?

It depends on the door. Single doors typically take a rim or mortise device. Pairs take vertical rod devices, or a rim device with a removable mullion.

Fire rating, traffic, and whether the door is electrified narrow the choice further.

Who pays for a warranty callback that turns out to be installation?

That's between you and the installer, but the diagnosis comes first.

Many "defective" products are adjustment or installation problems, and knowing which saves an argument.

Can work be scheduled around patient care?

Yes. Work is planned by unit and time of day so rated doors aren't left out of service.

Do you write schedules from scratch?

Yes — written for the building's traffic, environment, occupancy, and code requirements, not copied from the last job.

Can a door with a closer use standard hinges?

It shouldn't. A closer puts constant load on the hinges. Ball-bearing hinges are the standard for any door with a closer.

Will an electronic lock work on our existing door?

If the door closes and latches cleanly now, usually yes.

If it doesn't, that has to be fixed first or the new lock will get blamed for the old problem.

Can you diagnose a fault you can't reproduce?

Often, yes. Wear marks, alignment, power readings, and the conditions when it fails usually point to the cause.

What do we get afterward?

A dated written record for every rated opening: what was inspected, what failed, and what was corrected.

Is this done remotely?

Yes. Drawings, specs, and submittals can all be reviewed remotely, anywhere.

Why does ice build up at the threshold?

Usually water getting in at the sill because the sweep is worn or missing, or a door bottom that isn't sealing.

In Central New York, that ice can also hold the door off the latch.

Can we lock our exit doors at night?

You can secure them from the outside, which is what exit devices are designed to do.

What you can't do is anything that stops people inside from getting out while the building is occupied: chains, padlocks, slide bolts, or blocking the door.

What is a master key system, and do we need one?

One key opens many doors, while each door still has its own key.

It makes sense once a building has more than a handful of doors and more than a few key holders — as long as it's designed and documented before keys are cut.

Is a maintenance plan worth it for a small building?

If the building has rated doors, a busy entrance, or a door that keeps failing, usually yes. If not, an annual check may be enough.

Do you program access control panels?

The focus is the opening: the lock, strike, power, and transfer.

I work alongside whoever runs the panel so the door and the system behave the same way.

Can you work from photos?

For scoping, yes. Tell me what the door is doing through the form, and once we've talked I'll ask for photos. You'll know whether it's a quick fix before anyone mobilizes.

What if the quote is fine?

Then that's what you'll hear.

Why does our pair of doors latch at the top but not the bottom?

On vertical rod devices, the bottom rod and latch wear fastest. They get hit by carts and floor equipment, and threshold wear, ice, and salt change how they engage.

It's usually an adjustment or a bottom-latch repair. Some buildings remove bottom rods entirely ("less bottom rod") where the code and the door rating allow it.

What are restricted keys?

Keys on a patented or restricted keyway that can only be duplicated through an authorized source, with a record of who has them.

They're how a key system stays under control after a few years of turnover.

Who can perform the inspection?

NFPA 80 requires a person with knowledge and understanding of the operating components of the door being inspected.

Your insurer or AHJ may have its own expectations — worth checking before you schedule.

Why does my door latch fine in summer and not in winter?

Usually two things are happening. Closer fluid thickens in the cold, which slows the whole cycle, so a closer set correctly in July delivers noticeably less latching speed in January.

On entrances and vestibules, building pressure is often the bigger factor: heated air pushes against the door and holds it off the strike.

Either way, it's almost always an adjustment, not a replacement. If the door latches when you push it closed by hand, the door and strike are fine and the closer needs its latch speed turned up.

How long should a commercial door closer last?

A good-quality closer on a properly sized and adjusted opening can last many years, even on a busy entrance. The ones that fail early are usually undersized for the door, mounted with the wrong arm, or never adjusted after installation.

For high-traffic doors, look for closers rated ANSI/BHMA A156.4 Grade 1.

Will a new closer fit the existing holes?

Sometimes. Different brands and models use different mounting patterns. When they don't line up, a drop plate or adapter plate can usually fit the new closer without new holes in the door or frame.

That matters on fire-rated doors, where field modifications are restricted.

Can our maintenance staff adjust closers themselves?

Basic speed adjustments, yes — carefully, a small turn at a time. Turning a valve out too far can let fluid out and ruin the closer.

Spring power, backcheck, arm changes, and anything on a fire door are better left to someone who does it every day.

Why did an inspector flag our closer?

The most common reasons are a fire door that doesn't close and latch on its own, a hold-open that doesn't release on alarm, missing or damaged parts, and opening force too high for ADA. ADA's 5-pound limit applies to interior doors; fire doors and exterior doors follow different rules.

Most of these are fixed with adjustment or a parts change, not a full replacement.

Ask a question

Ask it here. Questions worth answering get written up and published, so the next person with the same problem finds the answer.

What is the opening doing, and what kind of building is it in? Detail helps.

Optional.

Optional.

Optional. Only used if you would like to be credited when the answer is published.

Optional — but without it there is no way to reply directly.