Seal the opening. Keep the winter outside.
If daylight shows around a door, the building is heating the parking lot. Central New York winters find every gap, and the fix is the whole perimeter, not just the obvious edge — sealing one side of an opening usually just moves the problem.
What This Covers
Weatherstripping
Compression and kerf-style seals replaced once they harden, tear, or flatten, matched to the door and frame so the door still closes under its existing closer. A seal that's too aggressive turns into a latching complaint within a week.
Thresholds & Sweeps
Thresholds set to a height that seals without becoming a trip hazard, plus sweeps and rain drips that keep water and wind at the sill. On an accessible route the threshold height is a code question, not a preference: thresholds are limited to 1/2 inch high, with beveled edges.
The Opening as a System
A draft at the latch side is often a hinge or alignment problem wearing the seal unevenly. Replacing the seal alone fixes it until the next season. Treating the opening as one system is what makes the repair last. On fire-rated doors, seals and gasketing have to be listed for the assembly, and the gap under the door can't exceed NFPA 80's limits — new flooring is a common way that gap changes.
Drafts are the door telling on itself.
Sealing problems show up in comfort complaints first and the heating bill second, and both usually arrive well after the underlying alignment problem started. The seal is the symptom more often than the cause.
Symptoms Worth a Second Look
- There is a noticeable draft standing at the door
- Daylight shows around the edges
- Water gets in at the sill
- Ice forms at the threshold
- Wind whistles through on gusty nights
- The seal is worn unevenly along one side
- The heating load keeps climbing
- The sweep drags, or is missing entirely
Questions About Thresholds & Weatherstripping
- Why does the door stop latching after new weatherstripping?
The seal is too aggressive for the closer. A seal that compresses hard pushes the door back off the strike.
The fix is the right seal for the gap, not a stronger closer.
- How high can a threshold be on an accessible entrance?
ADA limits thresholds to 1/2 inch, with beveled edges. Some older entrances are allowed up to 3/4 inch if beveled.
Higher than that is a trip hazard and a compliance problem.
- Can we add weatherstripping to a fire door?
Only products listed for use on fire-rated assemblies. Adding an unlisted seal can void the door's rating.
- Why does ice build up at the threshold?
Usually water getting in at the sill because the sweep is worn or missing, or a door bottom that isn't sealing.
In Central New York, that ice can also hold the door off the latch.
Related
Something here sound familiar?
Tell me what the opening is doing and what building it's in. A free 15-minute phone consult is often enough to tell what you're dealing with. For a full assessment, the door, frame, and hardware are looked at together, with the findings in writing.