A

ANSI
American National Standards Institute. Accredits the standards that govern door hardware testing; you see it paired with BHMA on grade designations such as ANSI/BHMA A156.2.
Armor plate
A protective plate covering the lower portion of a door, taller than a kick plate — typically 36 inches or more. Used where carts, pallet jacks or heavy traffic hit the door face.
Astragal
A strip covering the gap between the two leaves of a pair of doors. On fire-rated pairs it's a required component of the assembly, not a trim option.

B

Backset
The horizontal distance from the edge of the door to the center of the lock bore. Commercial standard is usually 2 3/4 inches; 2 3/8 inches is common residentially. Order the wrong one and the lock doesn't fit the prep.
Bevel
The slight angle machined on the lock edge of a door so it clears the frame as it swings. Also used to describe which way a door is handed.
BHMA
Builders Hardware Manufacturers Association. Writes the test standards behind the Grade 1, 2 and 3 designations and the finish codes used on hardware schedules.
Bored lock
A lock installed into round holes bored through the door face and edge — also called a cylindrical lock. The most common commercial lock type. Governed by ANSI/BHMA A156.2.

C

Closer
The device that returns a door to the closed position under controlled force and speed. Governed by A156.4, and the component responsible for most ADA opening-force and sweep-timing compliance.
Coordinator
A device on a pair of doors that ensures the inactive leaf closes before the active leaf, so the astragal and latching work in the right order. Required on many rated pairs.
Cylinder
The keyed component of a lock, containing the pins and plug. Interchangeable core cylinders allow rekeying by swapping the core rather than disassembling the lock.

D

Deadbolt
A bolt thrown by a key or thumbturn with no spring action, providing security rather than latching. On egress doors its use is heavily restricted by code.
Deadlatch
A small plunger beside the main latchbolt that prevents the latch from being retracted when the door is closed — the feature that stops a credit card attack. If it's landing in the strike hole instead of against the strike face, security is gone.
Dogging
Holding an exit device's latch retracted so the door pushes open freely. Legal on non-rated doors, done with a hex key or cylinder. Never permitted on a fire-rated door, which must latch positively.
Door position switch
A sensor reporting whether a door is open or closed, used by access control and alarm systems. Often the first thing to check when a system reports a door held open.

E

Electric strike
A strike that releases electrically, allowing the door to be pushed or pulled open without retracting the latch. The most common access control device on commercial openings.
Electrified lever
A lockset with the locking function controlled electrically at the lever rather than at the strike. Requires power transfer through the hinge or a transfer device.
Electromagnetic lock
A magnet and armature plate holding a door closed with no moving parts — a mag lock. Always fail-safe, and always subject to specific egress requirements for release.
Exit device
Panic hardware. A latching device released by pushing a bar or pad across the door, so the door opens under crowd pressure. Governed by A156.3.

F

Fail safe
Unlocks on loss of power. Required where egress or fire alarm release demands the door open. A mag lock is inherently fail safe.
Fail secure
Stays locked on loss of power. Appropriate for security openings where egress is provided mechanically from the inside by the lever or exit device.
Fire rating
The duration an assembly is tested to withstand fire, marked on the label — commonly 20, 45, 60, 90 or 180 minutes. Applies to the whole assembly, not the door alone.
Flush bolt
A bolt recessed into the edge of the inactive leaf of a pair, securing it top and bottom. Manual flush bolts are an ADA operability problem; automatic flush bolts release when the active leaf opens.
Frame prep
The machining in a frame for hinges, strike and closer reinforcement. Determines what hardware the frame can accept without field modification.

G

Gasketing
Seals around the perimeter of a door for smoke, sound, light or weather. Smoke gasketing is a required component on many rated assemblies.

H

Handing
Which side the hinges are on and which way the door swings, described as left hand, right hand, left hand reverse or right hand reverse. Determined standing outside the door. Get it wrong and the hardware physically won't fit.
Hinge
The pivot connecting door to frame. Commercial standard is a full mortise butt hinge; heavy or high-traffic doors may use continuous geared hinges instead.
Hold-open
A feature keeping a door open. On a fire door it's only acceptable through a device that releases on alarm — a mechanical hold-open on a rated door defeats the assembly.
Hollow metal
Steel door and frame construction, formed from sheet steel over an internal core. The standard for commercial and institutional openings. Specified by gauge and grade.

K

Keying
The scheme determining which keys operate which locks. A keying schedule documents it. See master key system.
Kick plate
A protective plate on the lower door face, typically 8 to 12 inches tall. Also the usual way to satisfy the ADA smooth-surface requirement at the bottom of the push side.
Knurling
A roughened texture on a lever or knob, used as a tactile warning that the door leads to a hazardous area. The 2010 ADA Standards dropped the requirement; some local codes still call for it.

L

Label
The permanent marking on a fire door or frame identifying its rating and listing agency. If it's painted over, removed or illegible, the assembly can't be verified as rated and fails inspection.
Latch protector
A plate covering the gap at the latch to prevent tampering or jimmying on outswinging doors.
LCN
A door closer manufacturer, part of Allegion. The 4040XP is a long-standing benchmark for heavy-duty commercial closers.
Lockset
The complete locking assembly on a door — lever or knob, latch, and cylinder. Bored, mortise and interconnected are the common commercial types.

M

Master key system
A keying arrangement where individual keys open their own doors and a master key opens a defined group. Adds a second shear line to each cylinder, which is why poorly designed systems can be defeated.
Mortise lock
A lock installed into a rectangular pocket machined into the door edge. More functions, greater durability and more security than a bored lock, at higher cost. Governed by A156.13.
Mullion
A vertical post between the leaves of a pair, giving each leaf a surface to latch against. Removable mullions allow the full opening to be cleared when needed.

N

NFPA 80
The standard for installation and maintenance of fire door assemblies, including the requirement that rated assemblies be inspected annually with a written record.

P

Panic hardware
See exit device. Strictly, panic hardware is for non-rated doors and fire exit hardware is the rated equivalent — the rated version can't be dogged.
Positive latching
The requirement that a fire door latch securely when it closes. A door that swings shut but doesn't latch will open under fire pressure and fails inspection.
Power transfer
The means of getting current from frame to door for electrified hardware — an electric hinge, a door loop, or a concealed transfer device. A frequent cause of intermittent access control faults as it flexes over years.
Prep
The machining in a door or frame for a specific piece of hardware. Hardware and prep must match; mismatches mean field modification, which on a rated door can void the label.

R

Rim device
An exit device mounted on the surface of the door face, latching to a strike on the frame or mullion. The simplest and most common exit device type.

S

Strike
The plate in the frame that the latch engages. Alignment between latch and strike is the single most common cause of doors that won't latch.
Surface bolt
A bolt mounted on the door face rather than recessed. Simple, visible, and generally an ADA operability problem on any door in an accessible route.

U

UL listing
Certification by Underwriters Laboratories that a product has been tested to a given standard. On fire doors, the listing is what the label references.

V

Von Duprin
An exit device manufacturer, part of Allegion. The 98/99 series is among the most widely installed commercial exit devices in North America.

W

Wire transfer
See power transfer.

49 terms.